Gas Requirements
M414038
36
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Pressure checks can be made at the shut-off valve
(refer to Figure 14).
Turn on gas and check all pipe connections (internal
and external) for gas leaks with a non-corrosive leak
detection fluid.
Purge air in gas service line by operating the tumbler
in the drying mode.
If burner does not light and unit goes into lockout,
open and close the door and restart. Repeat these steps
until burner ignites. Use pipe compound, resistant to
actions of L.P. Gas, on all pipe threads.
WARNING
Check all pipe connections, internal and
external, for gas leaks using a non-
corrosive leak detection fluid. To reduce
the risk of explosion or fire, DO NOT USE
AN OPEN FLAME TO CHECK FOR GAS
LEAKS! Gas connections should be
checked annually for leakage.
W314