Alliance Laundry Systems T433I Clothes Dryer User Manual


 
Installation
19
M414038
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Position and Level the Tumbler
For further assistance, refer to the Section on Location
Requirements.
The tumbler may be moved with or without the skid.
To remove the skid, unscrew the four shipping bolts,
and discard them.
To fit a 170 pound tumbler (with shipping skid)
through an 8 foot high door, you must remove the front
access panel. The upper 3 inches of the stove must also
be removed on 170 pound gas tumblers. Removing the
entire gas or steam heater assembly and the shipping
skid, will reduce the height of the 120 pound tumbler
to 70 inches (1778 mm), and the 170 pound tumbler to
75 inches (1905 mm).
Level the tumbler to within 1/8 inch (3 mm) from
front-to-rear (level on cylinder rib), and side-to-side
(level on top panel). Shim under corners to level and
stabilize unit. Tumbler must not rock.
Before Placing Tumbler into Service
1. Remove or open all panels and check accessible
bolts, nuts, screws, terminals and fittings for
tightness.
2. Check V-belt tension and adjust if necessary.
Refer to appropriate paragraphs in Adjustments
Section.
3. Replace all panels and guards.
4. Turn on electrical supply to tumbler.
5. Open supply valve for gas or steam.
6. After performing the previous checks, start
the tumbler by pressing START (hold for
approximately 3 seconds). Release the start
button and open the loading door. The cylinder
should stop rotating within 7 seconds after the
door is opened a maximum of 2 inches
(50.8 mm) plus or minus 1/4 inch (6.35 mm). If it
does not, adjust the loading door interlock. Refer
to the appropriate paragraph in Adjustments
Section.
7. Gas tumblers: Start the tumbler and check the
burner flame. Adjust the gas inlet shutter as
required. Refer to the appropriate paragraph
in Adjustments Section.
IMPORTANT: The Electronic Ignition system will
attempt to light the gas by sparking for the trial
for ignition period. If gas does ignite within this
period, the ignition control will go into a safety
lockout and the valve will no longer open until the
control is reset. Refer to Table 1. It may be
necessary to restart several times to bleed air out of
gas lines. To reset, open and close loading door,
then start.
Table 1
If lockout condition persists, check that the manual
gas shut-off valve is in the open position and that
the gas service is properly connected. If condition
still persists, remove tumbler from service.
8. Load the cylinder with a full load of clothes or
clean rags and run to remove oil or dirt from
cylinder.
Location
Prepurge
Time
(seconds)
Trial for
Ignition
(seconds)
Reset
Lockout
Condition
By:
Australia 18 5 Open loading
door
Europe 18 10 Press reset
button on rear
of machine
All others
(MT/CD)
1 15 Open loading
door
All other
(OM)
1-3 10 Open loading
door