Alliance Laundry Systems T433I Clothes Dryer User Manual


 
Exhaust Requirements
M414038
32
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Figure 10
T472I
1 NOTE: Where exhaust duct pierces a combustible wall or ceiling, an opening having a diameter 4 in. (102 mm)
larger than diameter of exhaust duct shall be provided, with exhaust duct centered in opening.
2 Outlet for 1 Battery (Diameter same as largest station used.)
3 Outlet for 2 Batteries
4 45° Typical
LKJ I HG F ED CB A
L
3
4
1
2
D1
D2
Duct
Stations
10 Inch Duct 12 Inch Duct
120 Pound Models 170 Pound Models
D1 D2 D1 D2
A 10 in. (254 mm) 15 in. (381 mm) 12 in. (305 mm) 17 in. (432 mm)
B 15 in. (381 mm) 21 in. (533 mm) 17 in. (432 mm) 24 in. (610 mm)
C 18 in. (457 mm) 26 in. (660 mm) 21 in. (533 mm) 30 in. (762 mm)
D 21 in. (533 mm) 30 in. (762 mm) 24 in. (610 mm) 34 in. (864 mm)
E 24 in. (610 mm) 33 in. (838 mm) 27 in. (686 mm) 38 in. (965 mm)
F 26 in. (660 mm) 36 in. (914 mm) 30 in. (762 mm) 42 in. (1067 mm)
G 28 in. (711 mm) 39 in. (991 mm) 32 in. (813 mm) 45 in. (1143 mm)
H 30 in. (762 mm) 42 in. (1067 mm) 34 in. (864 mm) 45 in. (1143 mm)
I 32 in. (813 mm) 45 in. (1143 mm) 36 in. (914 mm) 52 in. (1321 mm)
J 33 in. (838 mm) 47 in. (1194 mm) 38 in. (965 mm) 54 in. (1372 mm)
K 35 in. (889 mm) 49 in. (1245 mm) 40 in. (1016 mm) 57 in. (1448 mm)
L 36 in. (914 mm) 51 in. (1295 mm) 42 in. (1067 mm) 60 in. (1524 mm)