Alliance Laundry Systems T433I Clothes Dryer User Manual


 
Installation
M414038
26
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Model 120FG INPUT: 87.8 kW
Table 2
NOTE: In addition to directions below, follow all
instructions including verification and adjustment
of injector pressure.
1 Order as Regulated Natural Gas. No modification
needed.
2 Order as Regulated Natural Gas. Apply
appropriate country sticker.
3 Order as Regulated Natural Gas. Apply
appropriate country and gas stickers.
4 Order as Unregulated with Unregulated Natural
Gas injectors. Apply appropriate country sticker.
5 Order as Unregulated with L.P. Gas injectors.
Apply appropriate country sticker.
6 Order as Regulated Natural Gas. Convert with
(3) 2.6 mm injectors Part No. M411376. Apply
appropriate country and gas stickers.
7 Order as Unregulated with L.P. Gas injectors. No
modification needed.
8 Order as Unregulated with L.P. Gas injectors.
Apply appropriate country sticker.
OPEN No Approval available.
Special Cases No additional kits are required to
convert from regulated to unregulated.
Gas
Type
GB IE PT ES IT DK NO SE FI DE NL BE FR AT
Gas
Family
& Group
Inject. 0
Inject. Qty
& Part. No.
Inlet
Press.
Gvnr./
Regltr.
Inject.
Press.
Nat.
Gas
1111122222 2
2nd
family
Group H
(E)
4.8 mm
3
M411372
20 mbar Yes 8.9 mbar
3
2nd
family
Group L
(LL)
4.8 mm
3
M411372
25 mbar Yes
12.0
mbar
44
2nd
family
Group E+
4.2 mm
3
M402295
20.25
mbar
No Unreg.
L.P.
Gas
555555
3rd
family
Group
B/P
2.6 mm
3
M411376
30 mbar No Unreg.
66
3rd
family
Group
B/P
2.6 mm
3
M411376
50 mbar Yes
26.4
mbar
77777 88
3rd
family
Group 3+
2.6 mm
3
M411376
28.37
mbar
No Unreg.