Alliance Laundry Systems 70269701R4 Clothes Dryer User Manual


 
Electrical Requirements
70269701
56
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
For 24 kW Models:
35 Pound Electric
Table 13
Serial Plate
Voltage
Terminal Block
Connections
Required
Current
(Amps)
Recommended
Fuse or Breaker
Rating (Amps)
Breaker
Poles
Recommended
Minimum
Conductor Size
[AWG (mm
2
)]
208V/60Hz/1ph
L1, L2, Neutral,
and ground
122 175 2 2/0 (67.5)
240V/60Hz/1ph
L1, L2, Neutral,
and ground
107 150 2 1/0 (53.5)
200V/60Hz/1ph
L1, Neutral,
and ground
122 175 1 2/0 (67.5)
200V/50Hz/1ph
L1, Neutral,
and ground
119 150 1 1/0 (53.5)
230-240V/50Hz/
1ph
L1, Neutral,
and ground
108 150 1 1/0 (53.5)
200-208V/60Hz/
3ph
L1, L2, L3,
and ground
71 90* 3 3 (26.7)
200V/50Hz/3ph
L1, L2, L3,
and ground
65 90* 3 3 (26.7)
230-240V/50Hz/
3ph
L1, L2, L3,
and ground
62 80* 3 4 (21.2)
240V/60Hz/3ph
L1, L2, L3,
and ground
62 80* 3 4 (21.2)
380V/50Hz/3ph
L1, L2, L3,
and ground
38 50* 3 6 (13.3)
400-415V/50Hz/
3ph
L1, L2, L3,
and ground
35 45* 3 8 (8.37)
460-480V/60Hz/
3ph
L1, L2, L3,
and ground
31 40* 3 8 (8.37)
* 3 Phase machines should not have fuses, breakers only.