Injector information at 0-2000 feet (0-600 meters) altitude.
* For Natural Gas, Group E+ applications, convert using L.P.
Gas model and replace injectors.
** For L.P. Gas, Group B/P with 50 mbar supply pressure,
convert using Natural Gas model, 431559 regulator spring kit
and injectors.
Table 3 (continued)
Country
Code
Gas Type Group
Supply
Pressure,
mbar
Injector
Pressure,
mbar
Capacity/
Model
Diameter,
mm
Quantity
Injector
Part No.
GB/IE/PT/
ES/IT/GR/
LU/CH
Natural Gas H 20 7.6
8.0
8.0
8.0
25
30
T30
35
3.9
4.0
4.0
4.6
1
1
2
1
M402980
M402992
M402992
M411511
L.P. Gas + 28 or 37 No Governor 25
30
T30
35
2.1
2.2
2.2
2.5
1
1
2
1
M401003
M401011
M401011
M406361
AT**
Natural Gas H 20 7.6
8.0
8.0
8.0
25
30
T30
35
3.9
4.0
4.0
4.6
1
1
2
1
M402980
M402992
M402992
M411511
L.P. Gas B/P 50** 28** 25
30
T30
35
2.1
2.2
2.2
2.5
1
1
2
1
M401003
M401011
M401011
M406361
CY/IS/MT
L.P. Gas B/P 30 No Governor 25
30
T30
35
2.1
2.2
2.2
2.5
1
1
2
1
M401003
M401011
M401011
M406361
HU
Natural Gas H 25 7.6
8.0
8.0
8.0
25
30
T30
35
3.9
4.0
4.0
4.6
1
1
2
1
M402980
M402992
M402992
M411511
L.P. Gas B/P 30 No Governor 25
30
T30
35
2.1
2.2
2.2
2.5
1
1
2
1
M401003
M401011
M401011
M406361
PL
Natural Gas H 20 7.6
8.0
8.0
8.0
25
30
T30
35
3.9
4.0
4.0
4.6
1
1
2
1
M402980
M402992
M402992
M411511
L.P. Gas 3P 37 No Governor 25
30
T30
35
2.1
2.2
2.2
2.5
1
1
2
1
M401003
M401011
M401011
M406361