Alliance Laundry Systems 70269701R4 Clothes Dryer User Manual


 
Electrical Requirements
53
70269701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
For T30 Gas and Steam Models
(For Total Machine):
Table 10
Serial Plate
Voltage
Terminal Block
Connections
Required
Current
(Amps)
Recommended
Fuse or
Breaker Rating
(Amps)
Breaker
Poles
Recommended
Minimum
Conductor Size
[AWG (mm
2
)]
120V/60 Hz/1ph
L1, Neutral,
and ground
16.0 20 1 12 (3.31)
208-240V/60Hz/
1ph
L1, L2, Neutral,
and ground
8.0 10 2 14 (2.08)
100V/60Hz/1ph
L1, Neutral,
and ground
22.0 30 1 10 (5.26)
200-220V/60Hz/
1ph
L1, Neutral,
and ground
11.6 15 1 14 (2.08)
100V/50Hz/1ph
L1, Neutral,
and ground
24.2 35 1 8 (8.37)
200V/50Hz/1ph
L1, Neutral,
and ground
15.0 20 1 12 (3.31)
230-240V/50Hz/
1ph
L1, Neutral,
and ground
15.0 20 1 12 (3.31)
200-208V/60Hz/
3ph
L1, L2, L3,
and ground
6.4 10* 3 14 (2.08)
240V/60Hz/3ph
L1, L2, L3,
and ground
6.4 10* 3 14 (2.08)
200V/50Hz/3ph
L1, L2, L3,
and ground
5.8 10* 3 14 (2.08)
230-240V/50Hz/
3ph
L1, L2, L3,
and ground
7.0 10* 3 14 (2.08)
380V/50Hz/3ph
L1, L2, L3,
and ground
3.0 10* 3 14 (2.08)
400-415V/50Hz/
3ph
L1, L2, L3,
and ground
3.2 10* 3 14 (2.08)
460-480V/60Hz/
3ph
L1, L2, L3,
and ground
3.3 10* 3 14 (2.08)
* 3 Phase machines should not have fuses, breakers only.