Alliance Laundry Systems 70269701R4 Clothes Dryer User Manual


 
Electrical Requirements
55
70269701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
For 21 kW Models:
30 Pound Electric
T30 Electric not available in single phase.
Table 12
Serial Plate
Voltage
Terminal Block
Connections
Required
Current
(Amps)
Recommended
Fuse or
Breaker Rating
(Amps)
Breaker
Poles
Recommended
Minimum
Conductor Size
[AWG (mm
2
)]
208V/60Hz/1ph
L1, L2, Neutral,
and ground
108 150 2 1/0 (53.5)
240V/60Hz/1ph
L1, L2, Neutral,
and ground
94 125 2 1 (42.4)
200V/60Hz/1ph
L1, Neutral,
and ground
108 150 1 1/0 (53.5)
200V/50Hz/1ph
L1, Neutral,
and ground
105 150 1 1/0 (53.5)
230-240V/50Hz/1ph
L1, Neutral,
and ground
95 125 1 1 (42.4)
200-208V/60Hz/3ph**
L1, L2, L3,
and ground
62*** 80* 3 4 (21.2)
200V/50Hz/3ph**
L1, L2, L3,
and ground
60 80* 3 4 (21.2)
230-240V/50Hz/3ph**
L1, L2, L3,
and ground
55*** 70* 3 4 (21.2)
240V/60Hz/3ph**
L1, L2, L3,
and ground
54*** 70* 3 4 (21.2)
380V/50Hz/3ph**
L1, L2, L3,
and ground
33*** 45* 3 8 (8.37)
380V/50Hz/3ph
(035E Model)
L1, L2, L3,
and ground
34 45* 3 8 (8.37)
400-415V/50Hz/3ph**
L1, L2, L3,
and ground
31*** 40* 3 8 (8.37)
460-480V/60Hz/3ph**
L1, L2, L3,
and ground
27*** 35* 3 8 (8.37)
* 3 Phase machines should not have fuses, breakers only.
** These serial plate voltages are only options available on the 30 Pound Single and Stacked electric models. Current (Amp) is for one
pocket only.
*** Per heater on T30 electric models, each has two heaters.