Alliance Laundry Systems 70269701R4 Clothes Dryer User Manual


 
Gas Requirements
70269701
40
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Turn on gas and check all pipe connections (internal
and external) for gas leaks with a non-corrosive
detection fluid. Purge air in gas service line by
operating the tumbler in the drying mode. If burner
does not light and unit goes into lockout, open and
close the door and restart. Repeat these steps until
burner ignites. Use pipe compound, resistant to
actions of L.P. Gas, on all pipe threads.
Figure 12
Check all pipe connections, internal and
external, for gas leaks using a non-
corrosive leak detection fluid. To reduce
the risk of explosion or fire, DO NOT USE
AN OPEN FLAME TO CHECK FOR GAS
LEAKS! Gas connections should be
checked twice a year for leakage.
W635
WARNING
TMB2007N
1 Gas Line to Tumbler Controls
2 Shut-Off Valve
3 Gas Supply Piping System
4 Gas “T” Fitting
5 6 in. (152 mm) Minimum Gas Pipe
6 Gas Pipe Cap
7 Dirt and Water Vapor Trap
8 Supply Pressure Tap
TMB2007N
1
2
3
4
5
6
7
8