Alliance Laundry Systems 70269701R4 Clothes Dryer User Manual


 
Electrical Requirements
70269701
54
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electrical Requirements for Electric
Models
Refer to Table 11, Table 12 and Table 13.
NOTE: Minimum wire sizes are obtained from
Canadian Electrical Code Table 2 for 75°C
Conductors and are intended for use as a guideline
only. Electrical connections should be made only by
a qualified electrical contractor in accordance with
all applicable local and national requirements.
NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.
NOTE: Use copper conductors only.
NOTE: Connect to individual branch circuit.
NOTE: 3 Phase Only – Each tumbler must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of “single
phasing” and causing premature failure of the
motor(s).
For 9 kW 25 Pound Electric Models:
For 12 kW 25 Pound Electric Models:
Table 11
Serial Plate
Voltage
Terminal Block
Connections
Required
Current
(Amps)
Recommended
Fuse or
Breaker Rating
(Amps)
Breaker
Poles
Recommended
Minimum
Conductor Size
[AWG (mm
2
)]
400V/50Hz/3ph
L1, L2, L3,
and ground
16 20* 3 12 (3.31)
Serial Plate
Voltage
Terminal Block
Connections
Required
Current
(Amps)
Recommended
Fuse or
Breaker Rating
(Amps)
Breaker
Poles
Recommended
Minimum
Conductor Size
[AWG (mm
2
)]
208V/60Hz/1ph
L1, L2, Neutral,
and ground
64 80 2 4 (21.2)
240V/60Hz/1ph
L1, L2, Neutral,
and ground
57 80 2 4 (21.2)
200V/50Hz/1ph
L1, Neutral,
and ground
63 80 1 4 (21.2)
230-240V/50Hz/
1ph
L1, Neutral,
and ground
58 80 1 4 (21.2)
200-208V/60Hz/
3ph
L1, L2, L3,
and ground
37 50* 3 6 (13.3)
200V/50Hz/3ph
L1, L2, L3,
and ground
36 50* 3 6 (13.3)
230-240V/50Hz/
3ph
L1, L2, L3,
and ground
33 50* 3 6 (13.3)
240V/60Hz/3ph
L1, L2, L3,
and ground
33 50* 3 6 (13.3)
380V/50Hz/3ph
L1, L2, L3,
and ground
20 25* 3 10 (5.26)
400-415V/50Hz/
3ph
L1, L2, L3,
and ground
18 25* 3 10 (5.26)
460-480V/60Hz/
3ph
L1, L2, L3,
and ground
16 25* 3 10 (5.26)
* 3 Phase machines should not have fuses, breakers only.