Alliance Laundry Systems 70269701R4 Clothes Dryer User Manual


 
Installation
25
70269701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Before Placing Tumbler into Service
1. Remove or open all panels, and check accessible
bolts, nuts, screws, terminals and fittings for
tightness.
2. Replace all panels and guards.
3. Turn on electrical supply to tumbler.
4. Open the supply valve for gas or steam heated
tumblers.
5. After performing the previous checks, start the
tumbler by pressing START. (Refer to the
Operating Manual for detailed instructions.)
Release the start button and open the loading
door. The cylinder should stop rotating within
seven seconds after the door is opened a
maximum of 2 inches (51 mm). If it does not,
adjust the loading door switch. Refer to
Adjustments section.
6. Gas Tumblers: Start the tumbler and check the
burner flame. Adjust the air inlet shutter as
required. Refer to the Adjustments section.
IMPORTANT: The electronic ignition system will
attempt to light the gas by sparking for the “trial
for ignition” period. Refer to Table 2. If gas does
not ignite within this period, the ignition control
will go into a safety lockout and the valve will no
longer open until the control is reset. It may be
necessary to retry several times to bleed air from
the gas lines. To reset, open and close the loading
door and restart tumbler.
If lockout condition persists, check that the manual
gas shut-off valve is in the “ON” position and that
the gas service is properly connected. If condition
still persists, remove tumbler from service.
7. Load the cylinder with a full load of clean rags
and run to remove oil or dirt from cylinder.
8. Wipe out the cylinder using an all-purpose
cleaner or detergent and water solution. Refer to
Figure 5.
Figure 5
If the tumbler does not meet ANY of the listed
requirements, remove tumbler from use. Refer to
Removing Tumbler from Service section.
Required for CE Models Only
Once machine is installed, please be sure to complete
the following items:
Review and verify machine operation with
customer.
Leave all literature and a signed Declaration of
Conformity with customer.
Review machine warranty information with
customer.
Apply warning sticker on front panel of machine,
in language appropriate to country of sale
(included in literature packet).
Location
Prepurge
Time
(seconds)
Trial for
Ignition
(seconds)
To Reset
Lockout
Condition:
CE and
Australia
18 10 Press reset
button on rear
of machine
All others
1-3 10 Open loading
door
Table 2
T452I
T452I