Alliance Laundry Systems 70269701R4 Clothes Dryer User Manual


 
21
70269701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
Pre-Installation Inspection
Upon delivery, visually inspect crate carton and parts
for any visible shipping damage. If the crate, carton, or
cover is damaged or signs of possible damage are
evident, have the carrier note the condition on the
shipping papers before the shipping receipt is signed,
or advise the carrier of the condition as soon as it is
discovered.
Remove the crate and protective cover as soon as
possible and check the items listed on the packing list.
Advise the carrier of any damaged or missing articles
as soon as possible. A written claim should be filed
with the carrier immediately if articles are damaged or
missing.
IMPORTANT: Warranty is void unless tumbler is
installed according to instructions in this manual.
Installation should comply with minimum
specifications and requirements detailed herein,
and with applicable local gas fitting regulations,
municipal building codes, water supply regulations,
electrical wiring regulations, and any other
relevant statutory regulations. Due to varied
requirements, applicable local codes should be
thoroughly understood and all pre-installation
work arranged for accordingly.
Location Requirements
The tumbler must be installed on a level floor capable
of supporting weight of tumbler fully loaded. Floor
covering materials such as carpeting or tile should be
removed.
To assure compliance, consult local building code
requirements. The tumbler must not be installed or
stored in an area where it will be exposed to water
and/or weather.
IMPORTANT: DO NOT block the airflow at the
rear of the tumbler with laundry or other articles.
Doing so would prevent adequate air supply to the
combustion chamber of the tumbler.
A typical tumbler enclosure is shown in Figure 1. Note
the minimum and maximum dimensions. Local codes
and ordinances must be complied with.
IMPORTANT: Install tumblers with sufficient
clearance for servicing and operation. Refer to
Figure 1.
IMPORTANT: Keep tumbler area clear and free
from combustible materials, gasoline and other
flammable vapors and liquids.
Material Required (Obtain Locally)
All Models
One disconnect switch or circuit breaker.
Gas Models
One gas shut-off valve for gas service
line to each tumbler.
Steam
Models
One steam shut-off valve for steam
service line to be connected upstream of
solenoid steam valve.
Steam shut-off valve for each condensate
return line.
Flexible steam hoses with a 125 psig
(pounds per square inch gauge)
(8.78 kg/sq. cm) working pressure for
connecting steam coils. Refer to
Figure 15 for sizing and connection
configurations.
Steam trap for steam coil outlet to
condensate return line.
Optional – Vacuum breaker for
condensate return line.
To reduce the risk of serious injury, install
lockable door(s) to prevent public access to
rear of tumblers.
W055
WARNING