• Call up the value preset to preset it as is for the X-axis.
• Canceling the key input before loading the preset value.
If the Load key has not yet been pressed, it is possible to cancel all of the input
numbers by pressing the Cancel key. After the numbers have been canceled, the
display returns to the value before key input. If the Load key has already been pressed,
use the preset operation again to set the correct value.
IMPORTANT
• Preset data stored in the KA counter is the data input by the most recent preset
operation.
• The preset data stored in the KA counter has been saved on the basis of coordinate
systems described later.
• If data is preset through operation of the touch signal probe or zero-approach function
(described later), the preset data stored in the KA counter will be changed to those
values.
• Do not displace any axis scale during numeric entry. If displaced during entry for
presetting, etc., the scale unit may be damaged due to an overrun.
• Even if the counter exceeds the counting range, Error 30 will not be displayed during
numeric entry. The error message will be displayed after numeric entry has been
completed.
• Do not displace any axis scale too much while presetting is being performed.
• Zero-adjustment cannot be performed at Coordinate 0.
No. 99MBE032A