American Dryer Corp. Super AD-50 Clothes Dryer User Manual


 
43
90 DAYS
Inspect and remove lint accumulation in customer-furnished exhaust duct work system from dryer's internal
exhaust ducting.
WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN
CREATE A POTENTIAL FIRE HAZARD.
WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION and VENTILATION AIR.
WARNING: INSPECT and REMOVE ANY LINT ACCUMULATION WHICH CAN CAUSE
THE BACK DRAFT DAMPER TO BIND OR STICK.
NOTE: A back draft damper that is sticking partially closed can result in slow drying and shutdown of
heat circuit safety switches or thermostats.
NOTE: When cleaning the dryer cabinet(s), avoid using harsh abrasives. A product intended for the
cleaning of appliances is recommended.
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION and EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws, (bearing set screws), non-permanent gas connections (unions, shut-off valves,
orifices, and grounding connections). Motor and drive belts should be examined. Cracked or seriously
frayed belts should be replaced. Tighten loose V-belts when necessary. Complete operational check of
controls and valves. Complete operational check of ALL safety devices (door switches, lint drawer switch,
sail switch, burner and hi-limit thermostats).
C. LUBRICATION
The motor bearings, idler bearings, and tumbler bearings are permanently lubricated.
NO LUBRICATION IS NECESSARY.