American Dryer Corp. Super AD-50 Clothes Dryer User Manual


 
23
NOTE: Contact Factory for electrical information not listed.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
SUPER ADG-50 (Gas) Non-Reversing
SUPER ADS-50 (Steam) Non-Reversing
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size
according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MIMIMUM
WIRE SIZE*
FUSING
CIRCUIT
BREAKER
DUAL ELEMENT
TIME DELAY
60 Hz 50 Hz 60 Hz 50 Hz
120 2 13 -- #10 20 -- 25
208 2 7.6 -- #14 10 -- 15
240 2 7 5 #14 10 8 15
208 3 4.4 -- #14 8 -- 15
240 3 4.4 5.5 #14 8 8 15
380/400 3/4 -- 3 #14 -- 5.6 15
416 3/4 -- 3 #14 -- 5.6 15
460/480 3/4 2.7 -- #14 5 -- 15
460 3 2.5 -- #14 4.5 -- 15
* AWG Stranded Wire ... for individual lenghts less than 100 feet.
SUPER ADG-50 (Gas) Reversing
SUPER ADS-50 (Steam) Reversing
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size
according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MIMIMUM
WIRE SIZE*
FUSING
CIRCUIT
BREAKER
DUAL ELEMENT
TIME DELAY
60 Hz 50 Hz 60 Hz 50 Hz
208 3 6 -- #14 10 -- 15
230/240 2 7 7 #14 12 12 15
380/400 3/4 -- 4 #14 -- 8 15
416 3/4 -- 4 #14 -- 8 15
460/480 3/4 4 -- #14 8 -- 15
460 3 5.6 -- #14 5.6 -- 15
* AWG Stranded Wire ... for individual lenghts less than 100 feet.