American Dryer Corp. Super AD-50 Clothes Dryer User Manual


 
22
CAUTION: The dryer must be grounded. A ground lug has been provided for this purpose.
NOTE: A separate circuit serving each dryer must be provided.
The only electrical connections to the dryer are the 3-phase (3ø) leads (L1, L2, L3, and sometimes
Neutral) and ground. Single-phase (1ø) power for the control circuit is done by the factory at the
contactor (relay), and no other wiring connections are.
NOTE: Electrically heated service (amperage) specifications/requirements not available at time of
printing. Contact factory for update.
NOTES:A. Fuse ratings (as listed in the charts on page 23) are duel element-time-delay-current
limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify
correct breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3ø dryers must be 3-Pole type.