American Dryer Corp. Super AD-50 Clothes Dryer User Manual


 
14
If the length of the duct run or quantity of elbows used exceeds the above noted specifications, the cross section
area of the duct work must be increased in proportion to the number of elbows or duct run added.
IMPORTANT: For extended duct work runs, the cross section area of the duct can only be increased
to an extent. For extended duct work runs, a professional HVAC firm should be
consulted for proper venting information.
VERTICAL VENTING
When single 12-inch vertical venting is used (refer to illus. B below), the duct work from the dryer outlet should
not exceed 75 feet. This calculation compensates for the use of a maximum of three (3) elbows including the
two (2) elbows creating the 180º (turned downward) outside outlet.
Illus. B