4. Non-Microprocessor (Computer) Models
a. Turn power on to the dryer.
b. Insert coin(s) - rotary meter type ONLY.
c. Select temperature by using rocker switch and selecting "HI TEMP," "LO TEMP," or "PERM PRESS."
d. Press "Push to Start" button to start the cycle.
e. Upon completion of the drying and cooling cycles the dryer will shut off.
NOTE: If the door is opened during a cycle, both the heat and motor will stop. Continuation of the
cycle will only resume after the door has been closed, and the "Push to Start" button is pressed.
L. SHUT DOWN INSTRUCTIONS
If the dryer is to be shut down (taken out of service) for a period of time, the following MUST BE performed;
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply (for GAS MODELS ONLY):
a. Shut off external gas supply shut off valve.
b. Shut off internal gas supply shut off valve located at the gas valve train area.
3. Discontinue the steam supply (for STEAM MODELS ONLY):
a. Shut off steam valves in the supply lines and the return lines.