American Dryer Corp. EURO-35 Clothes Dryer User Manual


 
20
b. Electric Models ONLY
IMPORTANT: Figures shown are for Non-Reversing Models ONLY. For reversing models contact
the factory.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the back side of the upper/top control door. In the case of 208 VAC or
240 VAC, the supply voltage must match the electric service specifications of
the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC and 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: 3-Phase (3ø) figures shown are for 3-wire service ONLY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
APPROX. AMP DRAW
EURO-35 (ELECTRIC)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according
to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
APPLIED VOLTAGE/PHASE
Kw 208/1ø 240/1ø 208/3ø 240/3ø 380/3ø 416/3ø 460/3ø
30 -- -- 88 77 -- 45 41
33 -- -- --- -- 53 -- --
36 -- -- 104 92 -- 53 48
40 -- -- -- -- -- 59 --