American Dryer Corp. EURO-35 Clothes Dryer User Manual


 
6
MAXIMUM CAPACITY (DRY WEIGHT) 75 lbs. 34 kg
BASKET (TUMBLER) DIAMETER 37" 94 cm
BASKET (TUMBLER) DEPTH 36" 91.5 cm
BASKET (TUMBLER) MOTOR 1 HP* .746 kw
DOOR OPENING (DIAMETER) 21-1/2"
54.61 cm
BASKET (TUMBLER) VOLUME 22.4 cu. ft. .634 cu.m.
DRYERS PER 20'/40' CONTAINER 10/20
DRYERS PER 6m/12m CONTAINER 10/20
DRYERS PER 45'/48' TRUCK 24/24
DRYERS PER 14m/15m TRUCK 24/24
VOLTAGE AVAILABLE 120-460v 1ø-3ø 3, 4w 50/60 Hz
APPROX. WEIGHT (UNCRATED) 833 lbs.
377.8 kg
APPROX. WEIGHT (CRATED) 883 lbs. 400.5 kg
HEAT INPUT 200,000 btuh 50,400 kcal/hr
AIRFLOW 1,200 cfm 33.98cmm
INLET PIPE CONNECTION 3/4" F.P.T.** --
OVEN SIZE
KW
BTUH
(60 HZ)
KCAL/HR
(50 Hz)
30 102,390 25,800
33 --
28,370
36 122,870 30,950
40 -- 34,390
APPLIED VOLTAGE/PHASE/APPROX. AMP DRAW***
KW
208/1ø 240/1ø 208/3ø 240/3ø 380/3ø 416/3ø
460/3ø
60 Hz 50 Hz 50/60 Hz 60 Hz 50 Hz 50/60 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz
30 -- -- -- 88 -- 77 -- -- -- 45 41 --
33 -- -- -- -- -- -- -- 53 -- -- -- --
36
--
-- -- 105 -- 92 -- -- -- 53 48 --
40
--
-- -- -- -- -- -- -- -- 59
--
--
VOLTAGE AVAILABLE 120-460v 1ø - 3ø 3, 4w 50/60 Hz
APPROX. WEIGHT (UNCRATED) 864 lbs. 392.7 kg
APPROX. WEIGHT (CRATED) 914 lbs. 415.5 kg
AIRFLOW 1350 cfm 38.23 cmm
COMPRESSED AIR VOLUME .75 cfh .02 cmh
AIR CONNECTION 1/8" F.P.T. --
STEAM CONSUMPTION BOILER HP NORMAL LOAD
238.7 lbs/hr 108.3 kg/hr 7
OPERATING PRESSURE SUPPLY CONNECTION** RETURN CONNECTION
125 psi max 8.6 bar 1" -- 1" --
Shaded areas are in metric equivalents
SECTION II
SPECIFICATIONS
A. SPECIFICATIONS
* EURO-35 50 Hz 1-phase (1ø) non-reversing dryers use a 3/4 HP motor. ALL EURO-35 reversing dryers
are supplied with two 3-phase motors standard: a 1 HP blower motor and a 1/2 HP drive motor.
** Size of piping to dryer varies with installation conditions. Contact factory for assistance.
*** Contact factory for information not listed, 3-phase (3ø) figures shown are for 3-wire service.
**** Specify air-operated or electromechanical steam damper system. Air-operated steam damper system
must be provided with clean, dry and regulated 80 psi +/-10 psi (552 kPa +/- 69 kPa) air supply.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
GasElectric
Steam****