American Dryer Corp. ADG-758 Clothes Dryer User Manual


 
46
MICROPROCESSOR (COMPUTER) MODELS
A. No L.E.D. (light emitting diode) display (for microprocessor [computer] models ONLY)...
1. Service panel fuse blown or tripped breaker.
2. Blown control circuit L1 or L2 1/2-amp (Slo Blo) fuse.
3. Failed microprocessor controller (computer).
4. Failed step down transformer (for models 380 volts or higher ONLY).
B. Drive motor is not operating (does not start)...
1. Microprocessor controller (computer) motor indicator dot and relay output L.E.D. (light emitting diode)
indicator dots are on ...
a. Failed drive motor contactor (relay).
b. Failed arc suppressor (A.S.) board (for Reversing Models ONLY).
c. Failed drive motor.
2. Microprocessor controller (computer) motor indicator dot and relay output L.E.D. (light emitting diode)
indicator dots are on, but motor output L.E.D. indicator is off ...
a. Failed microprocessor controller (computer).
C. Drive motor (for Reversing Models ONLY) operates in one direction only...stops and restarts in
same direction...
1. Failed drive motor contactor (relay).
2. Failed arc suppressor (A.S.) board.
3. Failed microprocessor controller (computer)...check output indicator.
D. Drive motor operates okay for a few minutes, and then stops and will not restart...
1. Motor is overheating and tripping out on internal overload protector ...
a. Motor air vents clogged with lint.
b. Low voltage to the motor.
c. Failed motor.
d. Basket (tumbler) is binding...check for obstruction.
e. Failed idler bearings or tumbler bearings.
f. Failed blower (impellor/fan)...out of balance (for Non-Reversing Models ONLY).