American Dryer Corp. ADG-758 Clothes Dryer User Manual


 
25
2. Technical Gas Data
a. Gas Specifications
b. Gas Connections:
Inlet connection ---------- 3/4-inch N.P.T.
Inlet supply size ----------- 3/4-inch N.P.T. (minimum)
Btu/hr input (per dryer) -- 175,00 (44,100 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must
be consistent between a minimum of 6.0 inches (14.92 millibars) and a maximum of 12.0 inches water
column (W.C.) - 29.9 millibars - pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap must be a consistent 10.5 inches water column (W.C.) - 26.1 millibars. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the
source (L.P. tank) or an external regulator must be added to each dryer.
TYPE OF GAS
Natural Liquid Propane
Manifold Pressure* 3.5 inches W.C. 8.7 mb 10.5 inches W.C. 26.1 mb
Inline Pressure 6.0 - 12.0 inches W.C. 14.92 - 29.9 mb 10.5 inches W.C. 26.1 mb
Shaded areas are in metric equivalents
* Measured at gas valve pressure tap when the gas valve in on.
TYPE OF GAS
L.P.
Conversion Kit
Part Number
ADC
MODEL
NUMBER
Rating
Rating
Natural Liquid Propane
Qty. D.M.S.*
Number
Qty. D.M.S.*
Part
Number
ADG-758 175,000 44,100 4 #30 140819 4 #49 140803
882230
Shaded area is stated in metric equivalent
* D.M.S. (Drill Material Size) equivalents are as follows:
Natural Gas ............... #30 = .1285" (.33 cm)
Liquid Propane Gas .. #49 = .0730" (.19 cm)