American Dryer Corp. ADG-758 Clothes Dryer User Manual


 
40
a. Upon completing installation of the replacement
Hot Surface Ignition (HSI) module, reestablish
power to the dryer.
b. The Hot Surface Ignition (HSI) module's "red"
indicator light will light for up to approximately
5-seconds (self check routine).
If the Hot Surface Ignition (HSI) module's "red"
indicator light stays on or flashes continuously,
then the HSI module is wired incorrectly or has
failed.
c. Start the drying cycle.
d. The hot surface ignitor will turn on. After approximately 4-seconds the hot surface ignitor will shut off and
the gas valve will be energized. Ignition (flame) should now be established.
e. With the burner flame on, remove the flame sensor wire from the S2 terminal of the HSI module. The
burner flame must shut off immediately.
f. Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.
g. The hot surface ignitor will turn on, and after approximately 4-seconds the hot surface ignitor will shut off.
The gas valve will be energized and the hot surface ignitor will shut off. Ignition (flame) should be
evident for approximately 7-seconds and then shut off.
h. The Hot Surface Ignition (HSI) module will attempt two (2) additional ignition trials after which the HSI
module will lock out and the "red" indicator light will flash continuously.
i. Functional check of the Hot Surface Ignition (HSI) Module is complete.
1) Replace the flame sensor wire from the S2 terminal to the HSI module.
2. Hot Surface Ignition (HSI) System - for Gas Models Only