21
Actual electrical wire connections are made to L1 and L2 terminals of the motor contactor located in
the rear service box mentioned on page 20. The ground connection is also made to the copper lug also
provided in this box.
SINGLE-P HASE (1ø) ELECTRICAL CONNECTION LEADS
BLACK
+
POSITIVE
WHITE
+
NEUTRAL
GREEN
+
GROUND
OR
L2
If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/
pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the
service breaker panel. In both cases, a strain relief must be installed where the wiring enters the
dryer.
2) 3-Phase (3ø) Wiring Connections (Hookup) - for NON-REVERSING MODELS ONLY
The electrical connections on ALL 3-phase (3ø) gas model and steam model dryers are made into the
rear service box located at the upper left area of the dryer.
NOTE: A CIRCUIT SERVING EACH DRYER MUST BE PROVIDED.
If local codes permit, power to a gas dryers can be made by the use of a flexible U.L. listed power
cord/pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the
service breaker panel. In ALL cases, a strain relief must be installed where the wiring enters the
dryer.