American Dryer Corp. AD-840 Clothes Dryer User Manual


 
23
Telephone: (508) 678-9000
Fax: (508) 678-9447
2) Remove and discard old filter.
3) Scrub filter housing clean and rinse with clean water.
4) Insert the new cartridge. There are rubber washers on the top and bottom of the carbon filter.
Make sure they stay in place.
5) Filter housing should be screwed on hand tight only. Make sure cartridge filter is lined up with the top
and bottom posts in the housing and the o-ring in the housing is clean, properly seated and lubricated.
ATTENTION: O-RING SHOULD BE LUBRICATED WITH FOOD GRADE GREASE ONLY.
6) Open the water supply valves previously shut off.
AFTER REPLACING THE POLISHING FILTER, plug the dispensing pump back into the power
outlet and reset the computer. Then purge air trapped in the system by vending water at the bay
until the amount of water dispensed is what it should be. Air trapped in the tubings during filter
replacement will cause machine to vend less than it should.
7) Run system and check for leaks around the housing. Perform a free chlorine test if the carbon filter
is replaced to check if any leakage around the cartridge is present.
B. AIR FILTER INSPECTION AND REPLACEMENT
1) Cap on filter housing can be snapped off for maintenance check. Remove the sponge-like coarse
filter in the housing and inspect filter paper inside for dirt (diagram 6). Replace filter when the white
filter paper turns grayish or when coarse filter is clogged
2) To replace, unscrew the complete housing from the elbow fitting and discard. Wrap teflon tape on
the threads of the new housing and screw housing on hand tight.
filter
filter cap
filter housing