American Dryer Corp. AD-840 Clothes Dryer User Manual


 
13
Telephone: (508) 678-9000
Fax: (508) 678-9447
ATTENTION
The reverse osmosis membrane in this machine is filled with a preservative solution and plugged for shipping.
The two lengths of tubing illustrated below will have to be reconnected before machine start-up. See diagrams
below.
Refer to “Miscellaneous Maintenance Technique, Section C” on page 39 of the installation and owner’s
manual for tubing removal and attachment technique. Push tubing into fittings firmly to prevent leakage.
As Shipped Reconnected for Normal Operation
CAUTION: WEAR PROTECTIVE CLOTHING, GLOVES AND SAFETY GLASSES
WHEN RECONNECTING TUBING. THE PRESERVATIVE SOLUTION
CONTAINS SODIUM BISULFITE AND GLYCERINE AND MAY CAUSE
SKIN AND EYE IRRITATION IN SOME INDIVIDUALS. WIPE UP ALL
SPILLS IMMEDIATELY.
6. Open the main water ball valve located inside the cabinet at the water inlet of the machine.
7. Plug machine into the electrical outlet. Refer to guidelines in the section “Electrical Information.”
WARNING: THE MACHINE IS SHIPPED WITH A PRESERVATIVE SOLUTION MADE
OF SODIUM BISULFITE AND (IN THE WINTER) GLYCERINE. MAKE
SURE THE SYSTEM IS THOROUGHLY PURGED BEFORE LETTING
ANYONE DRINK THE DISPENSED WATER. SEE STEPS 9 AND 10.
8. The display should blink the message: “SYSTEM” “PURGE” “DO NOT” “DRINK.” Purge cycle
starts automatically. Clear the dispensing bay of obstacles as water will come out of the dispensing
valve and into the drain basin. Discard ALL water dispensed until purge cycle is over. Cycle is over
when the display blinks “INSERT” and “COIN” or the amount for one gallon.