American Dryer Corp. AD-75V Clothes Dryer User Manual


 
113231-4 www.amdry.com 33
f. Once the Cool Down Cycle begins at the end of the heat cycle, the L.E.D. display will read COOL
DOWN TEMP ___/___ MINUTES REMAINING. At the end of the heat cycle, the dryer will shut
off the heat and continue the fan and basket (tumbler) until the Cool Down Time or temperature is
reached.
IMPORTANT: For more detailed information regarding the microprocessor controller (computer) on
your dryer, refer to the microprocessor user’s manual included with the dryer.
2. Dual Timer Dryers
a. Turn drying timer knob for a time of 20 minutes.
b. Select “High Temp.”
c. Push “Push to Start” button.
d. To stop dryer, open the main door.
M. SHUTDOWN INSTRUCTIONS
If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply:
a. GAS MODELS – discontinue the gas supply.
1) SHUT OFF
external gas supply shutoff valve.
2) SHUT OFF
internal gas supply shutoff valve located in the gas valve burner area.
b. STEAM MODELS – discontinue the steam supply.
1) SHUT OFF
external (location furnished) shutoff valve.
2) SHUT OFF
internal steam valves in the supply lines and the return lines.