American Dryer Corp. AD-75V Clothes Dryer User Manual


 
18 American Dryer Corp. 113231-4
A ground lug is provided in the rear electrical box to connect your service ground.
Single-Phase Electrical Lead Connections
Black
+
Positive
White or Red
+
Neutral
or L2
Green
+
Ground
FOR 208-240V APPLICATIONSFOR 110V APPLICATIONS
4. Electrical Connections
A wiring diagram is located inside the control box for connection data.
If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/pigtail
(wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker
panel. In both cases, a strain relief must be installed where the wiring enters the dryer.
a. Gas and Steam Models Only
IMPORTANT: A separate protected circuit must be provided to each dryer.
1) Single-Phase (1ø) Wiring Connections/Hookup
The electrical input connections on
ALL single-phase (1ø)
gas dryers and steam dryers are made into the rear service
box located at the upper left area of the dryer.