113231-4 www.amdry.com 15
F. ELECTRICAL INFORMATION
1. Electrical Requirements
ALL electrical connections must be made by a properly licensed and competent electrician. This
is to ensure that the electrical installation is adequate and conforms to local and state regulations or codes.
In the absence of such codes,
ALL electrical connections, materials, and workmanship must conform to
the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in
Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements stipulated
in this manual can result in personal injury or component failure.
NOTE: Component failure due to improper installation will VOID THE WARRANTY.
Each dryer should be connected to an independently protected branch circuit. The dryer must be connected
with copper wire only. DO NOT use aluminum wire, it could create a fire hazard. The copper
conductor wire/cable must be of proper ampacity and insulation in accordance with electric codes for
making
ALL service connections.
NOTE: The use of aluminum wire will VOID THE WARRANTY.
IMPORTANT: A separate protected circuit must be provided to each dryer.
NOTE: An individual ground circuit must be provided to each dryer, do not daisy chain.
Multiple Dryer Venting (Steam and Electric) with 10-Inch (25.4 cm) Diameter
1200 cfm (33.98 cmm) Exhaust Connections at Common Duct