American Dryer Corp. AD-75V Clothes Dryer User Manual


 
32 American Dryer Corp. 113231-4
L. PREOPERATIONAL INSTRUCTIONS
COIN MODELS
1. Microprocessor Controller (Computer)
a. When the microprocessor controller (computer) is in the ready state, the liquid crystal display (L.C.D.)
screen will display “Ready, Insert $XX.XX (amount) to Start”.
b. Insert coin(s). Once the correct “Amount to Start” has been inserted, the L.C.D. will display “Select
Temperature”.
c. Select temperature by pressing “HI,” “MED,” or “LO.” The cycle will start and the liquid crystal
display (L.C.D.) will display the Dry Cycle selected and the remaining time.
d. The dryer will continue through the drying and cooling cycles, until the vended time has expired.
NOTE: To stop dryer, open main door or press the pause key. Continuation of the cycle will resume
only after the door has been closed and any of the three (3) temperature selection is pressed.
IMPORTANT: For more detailed information regarding the microprocessor controller (computer) on
your dryer, refer to the microprocessor user’s manual included with the dryer.
2. Mechanical Drop/Rotary Coin Meter or Slide Coin Meter
a. Insert coin and turn knob (rotary type meter), or for slide meter unit, push in coin chute.
b. Select Temperature.
c. Push the “Start” button.
d. To stop dryer, open the main door.
NON-COIN MODELS
1. Microprocessor Controller (Computer)
a. The light emitting diode (L.E.D.) display reads “READY” (no cycle in progress).
b. Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.e., key “D”).
c. The dryer will then start (i.e., blower, basket [tumbler], and heat).
d. The light emitting diode (L.E.D.) display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.
NOTE: The dryer can be stopped at any time by pressing the “STOP/CLEAR”
O
key, at this time the
dryer will go into a cycle pause. If the “STOP/CLEAR”
O
key is pressed again at this point,
the cycle that was in progress will be cancelled and returned to the “READY” state.
e. When the programmed drying time has expired, the Phase 7 non-coin microprocessor controller (computer)
will proceed into the Cool Down Cycle.