GAS AND STEAM
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz 50 Hz
120 2 13.0 * 20 20
208 2 7.6 * 15 15
220 2 7.3 8.6 * 15 15
230 2 8.0 * 15 15
240 2 7.0 * 15 15
208 3 4.7 * 15 15
230 3 4.7 * 15 15
240 3 4.9 * 15 15
380 3 2.9 * 15 15
380 4** 3.1 * 15 15
400 4** 3.2 * 15 15
416 4** 3.1 * 15 15
460/480 3 2.8 * 15 15
IMPORTANT: The dryer must be connected to the electric supply shown on the data label. The
supply voltage must match the electric service specifications of the data label exactly.
208 VAC AND 230/240 VAC ARE NOT THE SAME.
IMPORTANT: The wire size must be properly sized to handle the related current.
NOTE: Component failure due to improper voltage application will VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
2. Electrical Service Specifications
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the
factory.
a. Gas and Steam Models Only
* AWG Stranded Wire Type – size wire as per National Electrical Code or local codes. 8/1/05
** 3-Wire available.