American Dryer Corp. AD-75V Clothes Dryer User Manual


 
113231-4 www.amdry.com 21
TYPE OF GAS
Liquid
Propane
Conversion Kit
Part Number
Btu/hour
Rating
kcal/hr
Rating
Natural Liquid Propane
Qty. D.M.S.* Part No. Qty. D.M.S.* Part No.
200,000
50,400
4 #29 140820 4 #47 140805 882575
b. Gas Connections:
Inlet connection -------------3/4” N.P.T.
Inlet supply size -------------3/4” Diameter Pipe (minimum)
Btu/hr input (per dryer) ----200,000 (50,400 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column pressure (W.C.).
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.
Shaded area is stated in metric equivalent
* Drill Measurement Size (D.M.S.) equivalents are as follows:
Natural Gas .......................... #29 = 0.1360” (3.4544 mm).
Liquid Propane Gas .............. #47 = 0.0785” (1.9939 mm).
3. Piping/Connections
ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST
EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas)
or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances
and must be done by a qualified professional. It is important that gas pressure regulators meet applicable
pressure requirements, and that gas meters be rated for the total amount of
ALL the appliance Btu being
supplied.
The dryer is provided with a 3/4” N.P.T. inlet pipe connection located at the upper left rear of the dryer.
The minimum pipe size (supply line) to the dryer is 3/4” diameter. For ease in servicing, the gas supply line
of each dryer must have its own shutoff valve.
The size of the main gas supply line (header) will vary depending on the distance this line travels from the
gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same line, etc.
Specific information regarding supply line size should be determined by the gas supplier.
NOTE: Undersized gas supply piping can create a low or inconsistent pressure, which will result in
erratic operation of the burner ignition system.