American Dryer Corp. AD-25 Clothes Dryer User Manual


 
5
Bad Coin Lockout
Each coin entry is monitored. Should someone tamper with the coin acceptor or attempt to insert a foreign
object, the microprocessor controller (computer) will “LOCK UP” and will not accept any entries until the reset
time has elapsed (approximately 15-seconds). Once the reset time has expired, the microprocessor controller
(computer) will automatically reset itself for the next coin entry.
Temperature Conversion
When the temperature conversion status is changed (i.e., from ºF to ºC), the microprocessor controller (computer)
will automatically convert ALL temperature related programs/parameters from Fahrenheit to Celsius and vice
versa. The microprocessor controller (computer) will perform this conversion within 2º Celsius. The programs
affected are:
1. Temperature Display Mode
2. Temperature Selections
3. Cool Down Temperatures
Drying Temperatures
Any of the three (3) temperature selections (HI/LO/PP) are programmable from a minimum of 100º F (38º C)
to a maximum of 190º F (88º C) in ten-degree increments or from a minimum 35º C (95º F) to a maximum of
90º C (194º F) in five-degree increments. Actual temperature programs are displayed at time of programming
for verification.
Cool Down Time
ALL three (3) temperature selections are programmable from a minimum of 0 to a maximum of 9 minutes in 1
minute increments.
Cool Down Temperatures
In the automatic or free dry modes, the cool down cycle termination is programmable from a minimum of 100º F
(38º C) to a maximum of 190º F (88º C) in ten-degree increments or, from a minimum of 35º C (95º F) to a
maximum of 90º C (194º F) in five-degree increments.
Automatic Mode
This program will cycle the dryer off when the preprogrammed dryness level (1 to 99) or maximum cutoff time
(Adrt) (1 to 99 minutes) has been reached, whichever comes first.