American Dryer Corp. AD-25 Clothes Dryer User Manual


 
7
SECTION II
INSTALLATION PROCEDURES
A. INSTALLATION
The dryer is mounted on a skid by four (4) bolts. The front two (2) bolts are located on the floor of the lint
compartment. The other two (2) are located on the base at the rear of the dryer.
NOTE: Always keep the dryer in an upright position.
B. LOCATION OF THE DRYER
Approximately 2 feet (0.609 meters) should be allowed at the rear of the dryer for the duct and for ease of
maintenance. The dryer should be level. The four (4) legs are adjustable. (Refer to the illustration below for
details). Other factors to keep in mind include the following:
1. The main duct of the dryer must be tapered.
2. The minimum increase in cross section area for each 6-inch (15.24 cm) duct added is 45 square inches
(290.32 square centimeters) and 75 square inches (483.87 square centimeters) for each 8-inch (20.32 cm)
duct added.
3. Ducts should enter the main duct at the bottom or on the side at no more than a 45º angle.
4. Each exhaust duct should enter the main duct at least 34-inches (86.36 cm) apart.
5. The dryer must be installed with a proper exhaust duct connection to the outside.
6. The dryer must be installed with provisions for adequate combustion and make-up air supply.