American Dryer Corp. AD-25 Clothes Dryer User Manual


 
47
SECTION VIII
FACTORY PRESET PROGRAMS
Unless otherwise specified at the time of ordering, the Phase 3 microprocessor controller (computer) has been
preprogrammed by the factory with the following parameters. Should changes be found necessary, please read
this manual carefully to thoroughly familiarize yourself with the Phase 3 programming characteristics.
Dual Coin
PL01 ºFAr
tInE
Grd
bUZ
Coin
FLS
bCrS
AtIn
Temperature in Fahrenheit
Timed mode
Antiwrinkle guard on
Antiwrinkle guard buzzer (tone) on
Coin(s) required to start
Display will flash in intervals between “FILL”
and “Amount To Start”
Bad coin reset
Accumulative time
PL02 drYL Dryness level set at 25
PL03 HIº F 180º
PL04 HICd Temperature - 100º
Ti me - 2 minutes
PL05 LOº F 120º
PL06 LOCd Temperature - 100º
Ti me - 2 minutes
PL07 PPº F 150º
PL08 PPCd Temperature - 100º
Ti me - 3 minutes
PL09 LCdE Left coin denomination - 10
PL10 rCdE Right coin denomination - 25
PL11 tPLC Time per left coin - 4 minutes
PL12 AtSt Amount to start - 25
PL13 AFAt Amount for additional time - 10
PL14 Adrt Automatic dry maximum time - 30 minutes
PL15 GdLY
Gont
Antiwrinkle guard off delay - 2 minutes
Antiwrinkle guard on time - 20-seconds
PL16 AGt Active Antiwrinkle guard time - 10 minutes