American Dryer Corp. AD-25 Clothes Dryer User Manual


 
6
Antiwrinkle
This program selection helps keep permanent press items wrinkle free, when they are not removed from the
dryer promptly at the end of the drying and cooling cycle. The owner programs the dryer to automatically restart
in the cool down cycle, if the clothes
are not removed in a preprogrammed amount of time. The Antiwrinkle
Program settings are:
1. Guard Delay Time---------- 1 to 9 minutes
2. Guard On Time ------------- 1 to 99-seconds
3. Active Guard Time --------- 1 to 99 minutes
Free Dry Mode
In this program mode, the computer automatically reverts to the automatic mode. However, no coins are
required to start the dryer.
Light Emitting Diode (L.E.D.) Flash Display
Programmable to allow the L.E.D. readout to display a choice of “FILL” (no cycle in progress), “Amount To
Start” (i.e., 25¢), or in the case of free dry, “FrEE.” This program selection also allows the L.E.D. display to
flash back and forth every 2-seconds from “FILL” to “Amount To Start” or, in the case of free dry, from “FILL”
to “FrEE.”
Audible Tone
In this program selection, a buzzer (tone) will sound for each coin inserted, program entry, or at the end of the
drying cycle and cooling cycle for a period of 5-seconds to indicate that the cycle is complete. Additionally, when
in the Antiwrinkle program, the buzzer (tone) will sound for 5-seconds at the end of the “Guard On Time.”
Temperature Display
This program selection enables the temperature in the dryer to be viewed (ºF or ºC) either while the dryer is off
or running. This service feature shows that the dryer is maintaining the selected temperature.
Diagnostics
ALL major circuits, including door, microprocessor temperature sensor, heat, and motor circuits are monitored.
Battery Backup (Optional)
This feature allows the microprocessor controller (computer) to maintain its operating status should a momentary
power interruption occur while the dryer cycle is in progress.