American Dryer Corp. AD-25 Clothes Dryer User Manual


 
61
6 MONTHS
Inspect and remove lint accumulation in customer furnished exhaust ductwork system. Clean lint/dust accumulation
from between fins of steam coil.
WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN
CREATE A POTENTIAL FIRE HAZARD.
NOTE: When cleaning dryer cabinet(s), avoid using harsh abrasives. A product intended for the
cleaning of appliances is recommended.
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws, (bearing setscrews), grounding connections, and nonpermanent gas connections
(unions, shutoff valves, and orifices). Inspect motor and drive belts. Cracked or seriously frayed belts should
be replaced. Tighten loose belts when necessary and check alignment. Complete operational check of controls
and valves. Complete operational check of ALL safety devices (door switch, lint drawer switch, sail switch,
burner, and lint chamber thermostats).
C. LUBRICATION
The motor bearings, idler bearings, and basket (tumbler) bearings are permanently lubricated, and no lubrication
is necessary. Some basket (tumbler) bearings are equipped with grease fittings. Should lubrication ever be
found necessary, use a general purpose lithium-based grease. (DO NOT use animal or vegetable-based
lubricants.) DO NOT overgrease. Be sure grease fitting is thoroughly cleaned of ALL foreign material before
greasing.