American Dryer Corp. AD-25 Clothes Dryer User Manual


 
52
B. AUTOMATIC ONLY (NON-REVERSING DRYERS)
Dip switch settings - Switch #1 - open
Switch #2 - closed
Switch #3 - closed
Switch #4 - open
Switch #5 - closed
Switch #6 - unimportant
Switch #7 - unimportant
Switch #8 - closed (open for dryness level tripler)
1. Display shows “F_d_.”
2. Enter fabric selection; “1-9” selection appears after the letter “F_” in display.
3. Enter desired dryness level; “1 (less dry) through 9 (more dry)” selection appears after the letter “d_” in
display.
4. Press “Enter/Start.”
5. Display reads “dr00” and will count upward until preset dryness level is reached.
6. At the end of the drying cycle, the dryer then starts the cooling cycle for 5 minutes, or until the temperature
drops to approximately 100º F (38º C). During the cooling cycle, the display shows “CL” in the left two (2)
digits, while the elapsed time from the initial start is displayed in the right two (2) digits.
7. At the end of the cooling cycle, an audible tone will sound, and the display will show “CC00” meaning the
cycle is complete. Door must now be opened to cancel “CC00” display.
C. AUTOMATIC/MANUAL PROGRAM SELECTABLE
(“AUTO” SELECTED, NON-REVERSING DRYERS)
Dip switch settings - Switch #1 - open
Switch #2 - closed
Switch #3 - closed
Switch #4 - open
Switch #5 - open
Switch #6 - unimportant
Switch #7 - unimportant
Switch #8 - closed (open for dryness level tripler)
1. Display shows “FILL.”
2. Enter auto selection, press AUTO 3 .
3. Display shows “F_d_.”
4. Refer to Section B “Auto Only” for instructions.