American Dryer Corp. AD-25 Clothes Dryer User Manual


 
18
Dual Coin
In the time accumulation mode, when using a dual coin acceptor, once the “Amount To Start” (“AtSt”) has been
inserted, the addition of a coin(s) yields more time. The amount of time accumulated for each additional coin
inserted is determined by the “Time Per Left Coin” (“tPLC”) program (PL11).
The “Time Per Left Coin” (“tPLC”) is determined by taking the “Total Vend Time” divided by the “Amount To
Start” (“AtSt”) (PL12) and then, multiplying by the “Left Coin Denomination” (“LCdE”).
Formula: (Total Vend Time/AtSt)(LCdE) = tPLC
Example No. 1: Using a 10¢/25¢ dual coin acceptor with the desired “Amount To Start” (“AtSt”) being 25¢
for 15 minutes, each additional 10¢ would yield 6 minutes:
Formula: (15/25)(10) = 6 minutes (tPLC)
Settings: PL09 (LCdE) ............10
PL10 (rCdE) .............25
PL11 (tPLC) ...............6
PL12 (AtSt) ...............25
Example No. 2: If the dryer is equipped with a 10¢/25¢ dual coin acceptor and the “Amount To Start” (“AtSt”)
is 35¢ for 14 minutes, each additional 10¢ inserted would yield 4 minutes, and each additional
25¢ would yield 10 minutes.
Formula: (14/35)(10) = 4 minutes (tPLC)
Settings: PL09 (LCdE) ............10
PL10 (rCdE) .............25
PL11 (tPLC) ...............4
PL12 (AtSt) ...............35
Example No. 3: If the dryer is equipped with a 10¢/25¢ dual coin acceptor and the desired “Amount To Start”
(“AtSt”) is 55¢ for 33 minutes, each additional 10¢ inserted would yield 6 minutes, and each
additional 25¢ would yield 15 minutes.
Formula: (33/55)(10) = 6 minutes (tPLC)
Settings: PL09 (LCdE) ............10
PL10 (rCdE) .............25
PL11 (tPLC) ...............6
PL12 (AtSt) ...............55
NOTE: If the Total Vend Time cannot be divided evenly by the “Amount To Start” (“AtSt”), the “Time
Per Left Coin” (“tPLC”) must be rounded off.
Formula: (35/55)(10) = 6.36 - Round off to 6 minutes.