AEG L 14510 VI Washer User Manual


 
Water inlet (cold water connection only)
Connect the hose to a
tap with a 3/4” thread.
Installation should
comply with local
water authority and
building regulations’
requirements.
Set the hose correctly
by loosening the ring
nut. After positioning the inlet hose, be sure to tighten the ring nut again to
prevent leaks.
Do not connect to a hot water supply.
The inlet hose is provided with a water stop device,
which protects against damage caused by water
leaks in the hose which could develop due to nat-
ural ageing of the hose. This fault is shown by a red
sector in the window “A”. Should this occur, turn
the water tap off and refer to your Service Force
Centre to replace the hose.
Water drainage
TThis appliance is designed to be perma-
nently plumbed into your home's drainage
system using one of the following methods.
1. Into a drainage standpipe.
Firstly form a hook in the end of the drain
hose using the “U” piece” supplied.
Place the drain hose into your
standpipe, which should have
an internal diameter of approx-
imately 38mm thus ensuring
there is an air break between
the drain hose and standpipe.
47
Installation
A
P1199
U piece
supplied
P1074
30 cm (12")
38 mm (11.2)
standpipe
diameter
132984470.qxd 09/10/2006 10.12 Pagina 47