Commands and Queries Reference Alphabetical reference
OVSET? return the current programmed value of the Power Module’s OVP
threshold. The result is a <value>.
Syntax: OVSET? <ch>
Parameters the number of the channel to be queried.
Category Protection Type: Sequential
PEE assign new value to the Primary Event Status Enable Register. Re-
calculates <rqs> and <ist>.
Syntax PEE <int>
Parameters the value to be assigned to the Register - a decimal
number in the range 0 to 255 representing bits in the
Register.
Category Status Type: Sequential
PEE? return the value of the Primary Event Status Enable Register. The
value returned is a decimal number in the range 0 to 255 representing
the bits of the Register.
Syntax PEE?
Parameters none
Category Status Type: Sequential
PER? return the value of the Primary Event Status Register. The value
returned is a decimal number in the range 0 to 255 representing the
bits of the Register. The register is cleared.
Syntax PER?
Parameters none
Category Status Type: Sequential
POL change the Power Module’s output polarity. This command requires
the presence of the Polarity Reversal Relay Option.
Syntax POL <ch>,<int>
Parameters the number of the Power Module to be operated
upon.
the desired state of the Power Module’s output
polarity: a value of “0” means positive and a value
of “1” means negative output polarity.
Category Output Type: Overlapped
POL? return the current output polarity of the Power Module.
Syntax POL? <ch>
Parameters the number of the channel to be queried.
Category Output Type: Sequential
XMP 2600 Programming Manual
rev. 1.1 55