Alphabetical reference Commands and Queries Reference
IMIN? return the value of the minimum programmable current limit for the
Power Module.
Syntax IMIN? <ch>
Parameters the number of the channel to be queried.
Category Settings Type: Sequential
IOUT? return output current measurement of the Power Module. The
response is a <value>.
Syntax IOUT? <ch>
Parameters the number of the channel to be queried.
Category Read-back Type: Sequential
ISET program the current limiting of the Power Module’s output.
Syntax ISET <ch>,<value>
Parameters the number of the Power Module to be programmed.
the value to be set as the Power Module’s output
current limit. The lower limit of the programmed
value is IMIN. The upper limit of the programmed
value is the lower of ILIM and OCSET.
Category Settings Type: Overlapped
ISET? return the current programmed value of the Power Module’s output
current limit.
Syntax ISET? <ch>
Parameters the number of the channel to be queried.
Category Settings Type: Sequential
LLOCK lock / unlock the XMP 2600 in remote mode. When locked, the XMP
2600 front panel key “LOCAL” is disabled.
Syntax LLOCK <int>
Parameters the state to be assigned to the lock flag: a value of
“0” will unlock the XMP 2600 and a value of “1”
will lock the XMP 2600 in remote mode.
Category System Type: Sequential
LLOCK? return the state of the XMP 2600 Local Lock Flag. A value of “0”
means that the XMP 2600 is not locked and a value of “1” means that
the XMP 2600 is locked in remote mode.
Syntax LLOCK?
Parameters none
Category System Type: Sequential