![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/7/ea/7ea2c8b5-fd7b-42c5-bc3b-4d58e2b514d8/7ea2c8b5-fd7b-42c5-bc3b-4d58e2b514d8-bg4a.png)
DS2100 User's Manual (Preliminary) SECTION 3: WIRING AND INSTALLATION
PAGE 3-68
3.14.2 A & B Size Power Stage
- Fixed connector: 10 pins, male connector
-
Mating connector, 10 pins, female, supplied with the drive. Phoenix Contact (Part # PC4 HV/10-ST-7.62)
-
A size wiring: cable 14AWG (2.1 mm
2
). Wire stripping: 7 mm
-
B size wiring: cable 12AWG (3.3 mm
2
). Wire stripping: 7 mm
-
Tightening torque: 0.5Nm.
Pos.
Name
Function
J6.1 DC- DC Bus (-)
J6.2 DC+ DC Bus (+)
J6.3 RR Regeneration Resistance
J6.4 L1
Phase "L1", three-phase voltage input 230/460Vac ±10%
J6.5 L2
Phase "L2", ", three-phase voltage input 230/460Vac ±10%
J6.6 L3
Phase "L3", ", three-phase voltage input 230/460Vac ±10%
J6.7 PE Motor Protective Earth
J6.8 W Motor Phase W
J6.9 V Motor Phase V
J6.10 U Motor Phase U
- Fixed connector: 2 pins, male connector
-
Mating connector, 2 pins, female, supplied with the drive. Wago (Part # 231-102/026-000)
-
C & D size wiring: cable 14 AWG (2.1 mm
2
).
-
Stripping Length 8mm
Pos.
Name
Function
J8.1 24V +24V Logic Backup Supply
J8.2 0V Logic Supply Return
- PE Stud wiring: cable 6 AWG (13mm
2
)
Pos.
Name
Function
PE PE Protective Earth Stud on Chassis