![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/7/ea/7ea2c8b5-fd7b-42c5-bc3b-4d58e2b514d8/7ea2c8b5-fd7b-42c5-bc3b-4d58e2b514d8-bg24.png)
DS2100 User's Manual (Preliminary) SECTION 3: WIRING AND INSTALLATION
PAGE 3-30
3.7.1.3 Size C
EMC Filter,
Fuses etc.
See
Section 2
Installation
3 2 1
L1 L2 L3
Connector J6
C
PE
Stud
a.c. Mains
L1
L2
L3
Protective
Earth
Figure 3.17 Size C AC Mains Input Connection
- Fixed connector: 5 pins, male connector
- Mating connector, 5 pins, female, crimped supplied with the drive. (Molex 42816-0512)
- C size wiring: cable 8 AWG (8.4 mm
2
).
- PE Stud wiring: cable 6 AWG (13mm
2
)
Pos.
Name
Function
J6.3 L1
Phase "L1", three-phase voltage input 230/460Vac ±10%
J6.2 L2
Phase "L2", ", three-phase voltage input 230/460Vac ±10%
J6.1 L3
Phase "L3", ", three-phase voltage input 230/460Vac ±10%
PE PE Protective Earth Stud on Chassis
Table 3.5 J6 AC Mains Power connector, C Size