DS2100 User's Manual (Preliminary) SECTION 3: WIRING AND INSTALLATION
PAGE 3-28
3.7.1 AC Mains Power Source Connection
3.7.1.1 Size mA
EMC Filter,
Fuses etc.
See
Section 2
Installation
4 5 6
L1 L2 L3
Connector J6
A
4 5 6
L1 L2 L3
Connector J6
A
PE
Stud
PE
Stud
a.c. Mains
L1
L2
L3
Protective
Earth
Figure 3.15 mA AC Mains Input Connection
- Fixed connector: 12 pins, male connector
- Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-7.62)
- mA size wiring: cable 14 AWG (2.1 mm
2
). Wire stripping: 7 mm.
- PE Stud wiring: cable 6 AWG (13mm
2
)
- Tightening torque: 0.5Nm.
Pos.
Name
Function
J6.4 L1
Phase "L1", three-phase voltage input 230/460Vac ±10%
J6.5 L2
Phase "L2", ", three-phase voltage input 230/460Vac ±10%
J6.6 L3
Phase "L3", ", three-phase voltage input 230/460Vac ±10%
PE PE Protective Earth Stud on Chassis
Table 3.3 J6 AC Mains Power connector, mA Size