A SERVICE OF

logo

SECTION 3: WIRING AND INSTALLATION DS2100 User's Manual (Preliminary)
PAGE 3-45
3.11.2.2 Size A, B
PE
GND (J6.7)
Moto
r
U (J6.10)
V (J6.9)
grounding of shield
via connector clamp
W
(
J6.8
)
V
W
U
grounding of shield
via connector clamp
(or RF connection to
ground screw in
case of terminal board)
J6
DS2100 A, B
Figure 3.30 DS2100 A, B Motor Power Connection
- Fixed connector: 10 pins, male connector
- Mating connector, 10 pins, female, supplied with the drive. Phoenix Contact (Part # PC4 HV/10-ST-7.62)
- A size wiring: cable 14AWG (2.1 mm
2
). Wire stripping: 7 mm
- B size wiring: cable 12AWG (3.3 mm
2
). Wire stripping: 7 mm
- Tightening torque: 0.5Nm.
Pos.
Name
Function
J6.7 GND Motor Protective Earth
J6.8 W Motor Phase W
J6.9 V Motor Phase V
J6.10 U Motor Phase U
Table 3.19 J6, Motor connector, A,B Size