![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/7/ea/7ea2c8b5-fd7b-42c5-bc3b-4d58e2b514d8/7ea2c8b5-fd7b-42c5-bc3b-4d58e2b514d8-bgd.png)
SECTION 3: WIRING AND INSTALLATION DS2100 User's Manual (Preliminary)
PAGE 3-7
3.1.4 Serial Set-up Terminal (User-Supplied)
An RS-232 interface should be established for individual servo-drive communications, using a PC. The PC can run
Moog's WinDrive Windows-based user-interface program.
3.1.5 Control-Backup Power Input (User Supplied)
The DS2100 requires a control power source to supply backup-power for the control electronics. This control-backup
power is useful where the user requires that the DS2100 does not loose absolute position data or status information when
AC mains power is removed from the DS2100.
The user is directed to the local Moog sales office or authorised distributor for a recommended list of these control
power source devices.
The 24V
dc
control power option allows high voltage motor power to be removed from a DS2100 Series Servo-drive
without losing control power.
The acceptable voltage range for this supply is 24V
dc
±10% with a minimum current rating of 2A
dc
per DS2100 Series
Servo-drive connected. A low cost unregulated DC supply is adequate.
NOTE - The 24V
dc
power supply must be compliant with the
requirements of the EU EMC Directive. The 24V
dc
output from the
power supply must be Safety Extra Low Voltage (SELV - as defined
by European standard EN 60950).
Required for
CE-Compliance
The personal computer using Windrive is a service engineering tool
only and must be installed so that use of the key sequences which allow
control of the machine functions is accessible to authorised qualified
service personnel only. All such service set-up computers must be CE -
marked as compliant with the EU EMC Directive.
Required for
CE-Compliance
The G361-x003 &-x006 MUST have a 24V
dc
logic backup supply
connected for the drive to operate. No internal high voltage backup is
provided on these smaller models.