![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/d0/6d0316e0-be5f-44f5-a6c8-a70fb423f0cf/6d0316e0-be5f-44f5-a6c8-a70fb423f0cf-bg1a1.png)
417
Chapter 4, Description of Fields
Fields
210 NEXT I
220 END
Screens Where Field is Present
CDMA MOBILE REPORTED PILOT STRENGTH
Swept Pwr (CDMA Swept Power Measurement)
This field allows for arming the swept power measurement.
GPIB Example
“CDMA:SWEPtpower:TRIGger[IMMediate]“
arms the measurement.
Operating Considerations
Selecting Arm prepares the Test Set to expect an amplitude trigger from the mobile
station so that the Test Set can perform a swept measurement.
It is also necessary to send the following command once before arming the
measurement:
“CDMA:SWEPtpower:TRIGger:MODE:\RETRigger:SINGle“
Screens Where Field is Present
CDMA SWEPT POWER MEASUREMENT (When the Controls field is set to
Main)
Sync (Sector A Power)
This field allows the entry of Sync E
c
, the sync channel energy per PN chip
relative to the total sector power.
GPIB Example
“DISP CGEN;CDMA:CELL:ASECtor:SYNC:POWer -16“
sets Sector A pilot power to −16 dB.
Operating Considerations
As the sync level is varied, OCNS is automatically adjusted so that the total power
levels of pilot, sync, paging, traffic, and OCNS add up to Sector A power, I
or
.
Screens Where Field is Present
CDMA GENERATOR CONTROL