Speed Queen none Clothes Dryer User Manual


 
Gas Requirements
70256801
34
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Turn on gas and check all pipe connections (internal
and external) for gas leaks with a non-corrosive leak
detection fluid. Purge air in gas service line by
operating the tumblers in the drying mode. If burner
does not light and unit goes into lockout, open and
close the door and restart. Repeat these steps until
burner ignites. Use pipe compound, resistant to
actions of L.P. Gas, on all pipe threads.
Figure 13
WARNING
Do not use an open flame to check for gas
leaks! To reduce the risk of explosion or
fire check all pipe connections, internal
and external, for gas leaks using a non-
corrosive leak detection fluid. Check gas
connections annually for leakage.
W408
T135I
1 Gas Line to Tumbler
2 1/8 in. NPT Plug
3 Gas Supply Piping System
4 Gas “T” Fitting
5 6 in. (152 mm) Minimum Gas Pipe
6 Gas Pipe Cap
7 Dirt and Water Vapor Trap
8 Shut-Off Valve
T378I
1
2
3
4
5
6
7
8