Speed Queen none Clothes Dryer User Manual


 
Installation
25
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Model 50CG
Table 3
NOTE: Follow all instructions including
verification and adjustment of injector pressure.
1 – Order as Regulated Natural Gas. No modification
needed.
2 – Order as Regulated Natural Gas. Apply
appropriate country sticker.
3 – Order as Regulated Natural Gas. Apply
appropriate country and gas stickers.
4 – Order as Unregulated Natural Gas. Apply
appropriate country sticker.
5 – Order as Unregulated L.P. Gas. Apply appropriate
country sticker.
6 – Order as Regulated Natural Gas. Convert with
regulator spring kit Part No. M411334 and (2) 2.1 mm
injectors Part No. M401003. Apply appropriate
country and gas stickers.
7 Order as Unregulated L.P. Gas. No modification
needed.
8 – Order as Unregulated L.P. Gas. Apply appropriate
country sticker.
OPEN – No Approval available.
Special Cases Regulated Gas Valve may be
converted to Unregulated with block-open kit Part No.
M400763.
Gas
Type
GB IE PT ES IT DK NO SE FI DE NL BE FR AT
Gas
Family &
Group
Inject.
0
Inject. Qty
& Part. No.
Inlet
Press.
Gvnr./
Regltr.
Inject.
Press.
Nat.
Gas
1 1 1 1 1 2 2 2 2 2 2
2nd family
Group H
(E)
3.7 mm
2
M401000
20 mbar Yes 8.9 mbar
3
2nd family
Group L
(LL)
3.7 mm
2
M401000
25 mbar Yes 12.6 mbar
4 4
2nd family
Group E+
3.0 mm
2
M401017
20.25
mbar
No Unreg.
L.P.
Gas
5 5 5 5 5 5
3rd family
Group
B/P
2.1 mm
2
M401003
30 mbar No Unreg.
6 6
3rd family
Group
B/P
2.1 mm
2
M401003
50 mbar Yes 28.5 mbar
7 7 7 7 7 8 8
3rd family
Group 3+
2.1 mm
2
M401033
28.37
mbar
No Unreg.